H117 Linear Position Sensor

Intrinsically safe H117 is CSA approved for use in potentially explosive gas/vapour and dust atmospheres.
The H117 is designed for industrial and scientific feedback applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The unit is very compact and space-efficient with a small 19mm diameter body. The sensor is very robust, the body and push rod being made of stainless steel. The sensor is easy to install with mounting options including M5 male stud and M5 rod eye bearing. The push rod can be supplied free or captive, with male M5 thread or M5 rod eye.

Like all Positek® sensors, the H117 provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-350mm and with full EMC protection built in. The H117 offers a range of mechanical options, environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

View all Linear Sensors

 

Description

The Positek H117 slim-line linear position sensor is CSA approved for use in potentially explosive gas/vapour and dust atmospheres.
The H117 slim-line Linear Position Sensor is designed for industrial and scientific feedback applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The unit is very compact and space-efficient with a small 19mm diameter body. The sensor is very robust, the body and push rod being made of stainless steel. The sensor is easy to install with mounting options including M5 male stud and M5 rod eye bearing. The push rod can be supplied free or captive, with male M5 thread or M5 rod eye.

Like all Positek® sensors, the H117 provides a slim-line linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-350mm and with full EMC protection built in. The H117 offers a range of mechanical options, environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Follow us on Facebook

Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:

 

Measurement Range

Factory set to any length from 0-5mm to 0-350mm in increments of 1mm. For example, if your application requires 10" (254 mm) measurement, then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 254 mm.

 

 

Connector/Cable Options

Option Option Code
Connector Axial IP67 M12 4 pin J
Connector Radial IP67 M12 4 pin K
Cable with PG9 gland Axial, Gland IP68 L (3 core cable)
LQ (5 core cable)
Cable length - The standard length of cable supplied with a Positek position sensor is 50cm although you can specify any length you require up to a maximum of 15,000cm Specified in cm after the L/LQ e.g. L200 for 200cm 3 core cable from axial cable gland

 

Mounting Options

Option Option Code
M5 Rod eye on body (only with option "K") N
M5 x 08 male thread (body) Blank
Body clamps P
M8 rod eye on push rod U
M5 x 0.8 male thread (push rod) Blank

 

Push Rod Options

Option Option Code
Non-captive push rod V

 

<+/-0.1% FSO Linearity error (≥10mm stroke length) Option Code
Z650

Intrinsic Safety

CSA approval

This sensor is CSA approved to; Class I, Zone 0
Ex ia IIC T4 (Ta = -40°C to +80°C)
AEx ia IIC T4 (Ta = -40°C to +80°C)
AEx iaD IIIC T93°C(Ta = -40°C to +80°C)
Designates the sensor as belonging to; Class I, Zone 0: suitable for all areas except mining: can be used in areas with continuous, long or frequent periods of exposure to hazardous gas or dust

Gas:
Protection class ia IIC, denotes intrinsically safe for Zones 0, 1 & 2 and IIA, IIB and IIC explosive gases.
Temperature class T4: maximum sensor surface temperature under fault conditions 135°C.

Dust:
T93°C: maximum sensor surface temperature under fault conditions 93°C.
Ambient temperature range extended to -40°C to +80°C.

Galvanic Isolation Amplifier

It is imperative Positek® intrinsically safe sensors be used in conjunction with a galvanic barrier to meet the requirements of the product certification. The Positek G005 Galvanic Isolation Amplifier is purpose made for Positek IS sensors making it the perfect choice. Refer to the G005 datasheet for product specification and output configuration options.

The Positek® G005 Galvanic Isolation Amplifier is available with 0.5 - 9.5V or 4 - 20mA transmission output options or reverse outputs of 9.5 - 0.5 volts or 20 - 4 mA.

 

Dimensions

Body Diameter 35mm
Body Length Axial version: calibrated travel: +109.7mm
Radial version: calibrated travel +118.5mm
Travel Any stroke from 0-5mm to 0-350mm (e.g. 205mm)
Independent Linearity <±0.25% at 20°C
<±0.1% available on request
Temperature Coefficient <±0.01%/°C Gain & <±0.01%FS/°C Offset
Resolution Infinite
Noise

<0.02% FSO

Frequency Response >10KHz (-3dB);

 

Temperature Limits

Operating -40 to +80°C
Storage -40 to +125°C

 

Other

EMC Susceptibility EN 61000-6-2
EMC Radiated EN 61000-6-3
Vibration IEC 68-2-6: 10g
Shock IEC 68-2-29: 40g
MTBF 350,000 hrs 40°C Gf
Sealing IP67
Electrical Connections Screened cable or integral connector