The transmitter is an in head 4-20mA transmitter that connects to a standard thermocouple sensor and converts the sensor temperature to a 4-20mA signal.
An LED provides visual indication of sensor fault and programming mode. The transmitter is simply ranged and calibrated on the bench by using a single on-board push button switch, without the need for soldering links.
Digital technology ensures accurate and drift free linearisation to common curves, providing a level of performance not possible with earlier analogue types.
INPUT/td> | |
Input Type | |
KOS203TC | K-200 to 1370ºC |
J-200 to 1200ºC | |
T-200 to 400ºC | |
KOS203TC-2 | R-0 to 1760ºC |
S-0 to 1760ºC | |
B-0 to 1820ºC | |
Accuracy | ±0.04% FS ±0.04% rdg or 0.5ºC (which ever is greater) |
Linearisation | BS4937 / IEC 584, EN60584 |
Cold Junction tracking | 0.02ºC |
Cold Junction Range | -20 to 70ºC |
Min. Span | 10ºC |
Sensor Lead Length | Maximum length 3 metres to maintain CE Compliance |
Sample Rate | 500ms |
OUTPUT | |
Output Type | 4 to 20mA, 2 wire loop powered |
Maximum Output Range | 3.8 to 22mA |
Operating Voltage | 8 to 30Vdc |
Burnout | Up-scale ≥21mA (Down scale to order) Red programming LED comes on when temperature is outside operating range |
Protection | Reverse Polarity Protected |
Input/Output Isolation | 50Vdc (tested to 200V) |
Warm up time | 2 minutes till full accuracy |
EMC | BS EN61326 |
Ambient Temperature Range | -20 to 70ºC |
Ambient Humidity | 0 to 95% (non condensing) |
Ambient Storage | -40 to 90ºC |
Calibration Period | 12 months to maintain published Specifications. 5 years to twice specification. |
Dimension | 43mm Diameter 21 mm height |
Weight | 26 grams |
Default Range | Type K 0-1000ºC |
Content missing
Related Products
-
The KOS1200 is a (4 - 20mA) Signal isolator powered at input and output loops. The small size enables many more units to now be installed in the same physical space. Th...
KOS1200 Double Isolator
The KOS1200 is a (4 - 20mA) Signal isolator powered at input and output loops. The small size enables many more…
-
Ditel KOS1600BB Universal Isolating converter for Wheatstone bridge load cells and sensors.
KOS1600BB Converter
Ditel KOS1600BB Universal Isolating converter for Wheatstone bridge load cells and sensors.
-
Ditel KOS538A-Dual Isolator double loop isolator for DIN rail. Has two input 0/4-20mA (Source/sink), two output 0/4-20mA (Source). Isolation: 3-way 3kV/ 3.5kV between ch1 and ...
KOS538A-DUAL Isolator
Ditel KOS538A-Dual Isolator double loop isolator for DIN rail. Has two input 0/4-20mA (Source/sink), two output 0/4-20mA (Source). Isolation: 3-way…
-
- ±50Vdc or ±50 mA Full range inputs with sensor supply
- Voltage or current active / passive outputs
- Direct USB configuration offers system ...
DIN KOS1750 Signal Converter
±50Vdc or ±50 mA Full range inputs with sensor supply Voltage or current active / passive outputs Direct USB configuration…
-
The KOS1200 is a (4 - 20mA) Signal isolator powered at input and output loops. The small size enables many more units to now be installed in the same physical space. Th...
KOS1200 Double Isolator
The KOS1200 is a (4 - 20mA) Signal isolator powered at input and output loops. The small size enables many more…
-
Ditel KOS1600BB Universal Isolating converter for Wheatstone bridge load cells and sensors.
KOS1600BB Converter
Ditel KOS1600BB Universal Isolating converter for Wheatstone bridge load cells and sensors.
-
Ditel KOS538A-Dual Isolator double loop isolator for DIN rail. Has two input 0/4-20mA (Source/sink), two output 0/4-20mA (Source). Isolation: 3-way 3kV/ 3.5kV between ch1 and ...
KOS538A-DUAL Isolator
Ditel KOS538A-Dual Isolator double loop isolator for DIN rail. Has two input 0/4-20mA (Source/sink), two output 0/4-20mA (Source). Isolation: 3-way…
-
- ±50Vdc or ±50 mA Full range inputs with sensor supply
- Voltage or current active / passive outputs
- Direct USB configuration offers system ...
DIN KOS1750 Signal Converter
±50Vdc or ±50 mA Full range inputs with sensor supply Voltage or current active / passive outputs Direct USB configuration…
-
The KOS1200 is a (4 - 20mA) Signal isolator powered at input and output loops. The small size enables many more units to now be installed in the same physical space. Th...
KOS1200 Double Isolator
The KOS1200 is a (4 - 20mA) Signal isolator powered at input and output loops. The small size enables many more…
-
Ditel KOS1600BB Universal Isolating converter for Wheatstone bridge load cells and sensors.
KOS1600BB Converter
Ditel KOS1600BB Universal Isolating converter for Wheatstone bridge load cells and sensors.
-
Ditel KOS538A-Dual Isolator double loop isolator for DIN rail. Has two input 0/4-20mA (Source/sink), two output 0/4-20mA (Source). Isolation: 3-way 3kV/ 3.5kV between ch1 and ...
KOS538A-DUAL Isolator
Ditel KOS538A-Dual Isolator double loop isolator for DIN rail. Has two input 0/4-20mA (Source/sink), two output 0/4-20mA (Source). Isolation: 3-way…
-
- ±50Vdc or ±50 mA Full range inputs with sensor supply
- Voltage or current active / passive outputs
- Direct USB configuration offers system ...
DIN KOS1750 Signal Converter
±50Vdc or ±50 mA Full range inputs with sensor supply Voltage or current active / passive outputs Direct USB configuration…