H100 Cylinder Linear Position Sensor

Intrinsically safe H100 is CSA approved for use in potentially explosive gas/vapour and dust atmospheres. The H100 is designed for demanding hydraulic or pneumatic cylinder position® feedback applications where service life, environmental resistance and cost are important and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.

Overall performance, repeat-ability and stability are outstanding over a wide temperature range. The unit is highly compact and space-efficient, being responsive along almost its entire length. Like all Positek® sensors, the H100 provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-800mm and with full EMC protection built in.

The sensor is very rugged, being made of stainless steel with an inert fluoropolymer-sheathed probe and stainless steel target tube. The sensor is easy to install in cylinders and has a range of mechanical options. Environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

View all Linear Sensors

 

Description

The Positek H100 in-cylinder linear  position sensor is CSA approved for use in potentially explosive gas/vapour and dust atmospheres. The H100 in-cylinder linear position sensor is designed for demanding hydraulic or pneumatic cylinder position® feedback applications where service life, environmental resistance and cost are important and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.

Overall performance, repeat-ability and stability are outstanding over a wide temperature range. The unit is highly compact and space-efficient, being responsive along almost its entire length. Like all Positek® sensors, the H100 provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-800mm and with full EMC protection built in.

The sensor is very rugged, being made of stainless steel with an inert fluoropolymer-sheathed probe and stainless steel target tube. The sensor is easy to install in cylinders and has a range of mechanical options. Environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Follow us on Facebook

Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:

 

Measurement Range

Factory set to any length from 0-5mm to 0-800mm in increments of 1mm. For example, if your application requires 10" (254 mm) measurement, then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 254 mm.

 

 

Connector

Option Option Code
Connector - Hirschmann GD series Axial, IP65 J
Connector - Axial IP67, M12 - 4 pin. Without trim adjustment J + Z600
Connector - Axial IP67, M12 - 4 pin. With trim adjustment J + Z601
Cable with short gland Axial, IP67 M (3 core cable)
MQ (5 core cable)
Cable with axial gland, IP67 L (3 core cable)
LQ (5 core cable)
Cable length - The standard length of cable supplied with a Positek position sensor is 50cm although you can specify any length you require up to a maximum of 15,000cm Specified in cm after the L/LQ or M/MQ e.g. L200 for 200cm cable from axial cable gland

 

Mounting Thread Size Options

Option Option Code
M18 T
M20 N
3/4" UNF P

 

Target Flange Options

Option Option Code
Penny and Giles HLP100 V
Temposonics (M4 fixing) W
Parker Hannifin Cylinder Version X

 

<+/-0.1% FSO Linearity error (≥10mm and ≤400mm stroke length) Option Code
Z650

Intrinsic Safety

CSA approval

This sensor is CSA approved to:
Class I, Zone 0
Ex ia IIC T4 (Ta = -40°C to +80°C)
AEx ia IIC T4 (Ta = -40°C to +80°C)
Designates the sensor as belonging to; Class I, Zone 0: suitable for all areas except mining, : can be used in areas with continuous, long or frequent periods of exposure to hazardous gas / vapours. Protection class ia IIC, denotes intrinsically safe for Zones 0, 1 & 2 and IIA, IIB and IIC explosive gases. Temperature class T4: maximum sensor surface temperature under fault conditions 135°C. Ambient temperature range extended to -40°C to +80°C. Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.

Galvanic Isolation Amplifier

It is imperative Positek® intrinsically safe sensors be used in conjunction with a galvanic barrier to meet the requirements of the product certification. The Positek G005 Galvanic Isolation Amplifier is purpose made for Positek IS sensors making it the perfect choice. Refer to the G005 datasheet for product specification and output configuration options.

The Positek® G005 Galvanic Isolation Amplifier is available with 0.5 - 9.5V or 4 - 20mA transmission output options or reverse outputs of 9.5 - 0.5 volts or 20 - 4 mA.

 

Dimensions

Body Diameter 35mm
Body Length (to seal face) 43mm
Probe Length (from seal face) Measurement length +58mm
Target Tube Length Measurement length +30mm, ID 7.7mm, OD 9.45mm
Independent Linearity <±0.25% up to 450mm
<±0.50% over 450mm at 20°C
<±0.1% up to 400mm available on request
Temperature Coefficient <±0.01%/°C Gain & <±0.01%FS/°C Offset
Resolution Infinite
Noise

<0.02% FSO

Frequency Response >10KHz (-3dB);

 

Temperature Limits

Operating -40 to +80°C
Storage -40 to +125°C

 

Other

EMC Susceptibility EN 61000-6-2
EMC Radiated EN 61000-6-3
Vibration IEC 68-2-6: 10g
Shock IEC 68-2-29: 40g
MTBF 350,000 hrs 40°C Gf
Hydraulic Pressure 350 bar
Sealing IP67
Electrical Connections Screened cable or integral connector
Target A non-magnetic target tube is supplied with the sensor. This can be eliminated if the piston rod is made from non-magnetic steel and is drilled to a specific tolerance.